NEW Accessory: A 1942 AC/DC Current Clamp Probe


The new A 1942 AC/DC Current Clamp Probe is a special accessory for measurements in photovoltaic systems where there is a need to measure both the DC (from the photovoltaic panels) and the AC (on the AC side of a photovoltaic inverter) currents. The A 1942 AC/DC Current Clamp Probe has several measurement ranges (selectable using a rotary switch) for DC and AC currents; from a few milliamperes to a few hundred amperes.
The connection terminals (banana plugs) on the A 1942 AC/DC Current Clamp Probe are arranged for direct use with the MI 3108 EurotestPV and MI 3109 EurotestPV Lite.
Overview of A 1942 AC/DC Current Clamp Probe

AC current measurement range:
  • 4 A -> measuring constant 100 mV/A
  • 40 A -> measuring constant 10 mV/A
  • 200 A -> measuring constant 1 mV/A

DC current measurement range:
  • 40 A -> measuring constant 10 mV/A
  • 200 A -> measuring constant 1 mV/A

Applications:
  • AC and DC current measurements using MI 3108/3109 PV instruments.
  • AC and DC current measurements with supported DMMs.
  • AC and DC current measurements with an oscilloscope (connection adapter from banana to BMC connector not included).
Technical characteristics:

Measurement category clamp-meter
Maximum current
Pollution degree
Operation
Protection class
Altitude
Operation temperature
Storage temperature
Temperature coefficient
Range selection
E.M.C.


Safety

Power supply
Type of batteries
Consumption
Dimensions
Weight


CAT III 600V
200 A
2
Indoor
IP 30
< 2000 m
0 °C – 50 °C (<85 % H.R., <10 °C)
-20 °C – +60 °C (<75 % H.R.)
0.15 x / °C (< 18 °C or > 28 °C)
Manual selection
Emission: Class B
External mag. field rejection: < 30 A/m.
Meets EN 61326-1:2013
Meets EN 61010-1:2010 +A1:2019 and
EN 61010-2-032:2021 +A11:2021
3 V
2 x 1,5 V AA alkaline batteries
25 mA average
152 mm (L) x 66 mm (W) x 36 mm (H)
Approx. 250 g (battery included)
Specifications:

Range

DCA 0-40A
DCA 0-150A
DCA 150-200A
ACA 0-4A
ACA 0-40A
ACA 0-150A
ACA 150-200A


Output

DC 10mV/A
DC 1mV/A
DC 1mV/A
AC 100mV/A
AC 10mV/A
AC 1mV/A
AC 1mV/A


Accuracy @ CF = 1.41

±1.0% ± 0.02A
±1.0% ± 0.2A
-2.2% ± 0.2A
±2.0%±0.005A
±1.5% ± 0.03A
±1.5%±0.3A
-2.5%±0.3A
Note: The A 1942 AC/DC Current Clamp Probe has the same I/U constant as the existing A 1391 AC/DC Current clamp. The A 1942 AC/DC Current Clamp Probe will be added into the MI 3108 EurotestPV/MI 3109 EurotestPV Lite clamp selection menu.
Clamp comparison (measurement range):

A 1391 AC/DC Current clamp     A 1942 AC/DC Current Clamp Probe
40 A                                             40 A
300 A                                           200 A

The A 1942 AC/DC Current Clamp Probe is in stock and available immediately.